Fosroc Galvashield XP
Fosroc Galvashield® XP embedded galvanic anode series are used in concrete rehabilitation and new construction to mitigate the formation of new corrosion sites around the perimeter of a repair area or mitigate corrosion in new construction.
Get in touch Request a quoteMain uses
- Galvashield® anodes are used for the protection of steel reinforcement embedded in concrete from corrosion. When installed against the steel reinforcement, the anodes passiv-ate the steel, drastically extending its service life.
- Galvashield® XP embedded galvanic anodes series are used in concrete rehabilitation and new construction to pre-vent the formation of new corrosion sites around the perime-ter of a repair area or prevent corrosion in new construction.
Advantages
- Proven Technology - Galvashield® has more than 20 years track record in projects worldwide
- Focused protection - Provides localised corrosion prevention / control where it is needed the most, at the interface of the repair and the remaining contaminated concrete
- Type 1A anode - Alkali-activated to maintain activity of zinc, meets building code requirements that prohibit in-tentionally added constituents that are corrosive to rein-forcement within the repair area
- One-and-DoneTM connection - Innovative single wire connection that can be installed 2x faster than traditional 2 wire connections.
- BarFitTM Design - Grooved edges on Galvashield® XP2,XP4 and XPX anodes assist wih secure anode placement
- Steel Connection wires - Provides dependable steel-to-steel contact with no intermediate materials such as gal-vanizing that may compromise the long-term electrical connection.
- Economical - low cost method of providing galvanic corrosion prevention/ control to structures in demanding service conditions.
- Versatile - Suitable for chloride contaminated, pre-stressed/ post tensioned and new concrete.
- Zero Maintenance - Requires no external power source or system monitoring.
- Measurable - Anode performance can be monitored if required.
- Long Lasting – Up to 20 years service life* reduces the need for future repairs.
- ICRI CSP-3 (Concrete Surface Profile) - Raised edges provide increased surface profile to promote mechanical bond with repair mortars and concrete
Supporting documents for
Product Datasheet
Select your country to download datasheet
Product Safety Sheet
Select your country to download safety sheet
Unfortunately there was an error loading this content, please check back later.
There were no items found.
Case Studies
We pride ourselves on our customer service and knowledge, see how we have helped clients in the past.
Contact Fosroc
Whatever your enquiry, we'd love to hear from you.